POWERCOM
POWERCOM ULTIMATE SERIES (ULT-1000) 1000VA,RS-232 port,UPSMON s/w, (ABM),SNMP,opt.battery pack / High Frequency, True on-line UPS, Double Conversion Desgin, Double CPU Control,Pure Sine Wave Output,LCD display front panel |
|
INTERNATIONAL GROUND SHIPPING: For qualified orders, we will waive the Brokerage/Handling Fee for Custom Clearance and Documentation No other hidden fees will be collected from you when packages arrive. Guaranteed [ Detailed Explanation ] |
Product Description: GENERAL INFORMATION Model Type ULTIMATE LED Model Name ULT-1000 Power Rating 1KVA/700W AC INPUT AC Input Voltage 100V:76V~130V 110V:80V~138V 115V:83.5V~140V 120V:87V~140V 208V:152V~260V 220V:160V~276V 230V:167V~280V 240V:174V~280V AC Input Frequency 50 or 60 Hz+/-3 Hz AC Input Phase Single AC Input Power factor >= 0.98 AC OUTPUT AC Output Voltage 100V/110V/115V/120V or 208V/220V/230V/240V AC Output Frequency 50Hz/60Hz (Auto detection) AC Output Frequency Stability (+/-0.5%) AC Output Voltage Regulation (+/-2%) AC Output Powerfactor 0.7 (lagging) AC Output Hamonic distortion <3% of T.H.D. at linear load AC Output Overload detection 105% for 10 seconds and 130% +/- 10% for 300ms EFFICIENCY Field49 > 85% TRANSFER Transfer Power failure Recovery 0 ms Transfer Overload Disappear Auto transfer to UPS Transfer UPS to By Pass or Vice Versa N/A NOISE Noise Level 1m Distance < 45dBA PROTECTION Protection Spike 125 Joules BATTERY Battery Type Sealed lead acid battery, free-maintenance Battery Protection Cut off without draining any current when battery low Battery DC Voltage 36V BACKUP TIME Battery Backup Time Full Load 8 minutes Battery Backup Time Half Load 22 minutes Battery Recharge Time About 8 hours to 90% after fully discharged PHYSICAL Physical Weight kgs Tower 15 Physical Weight lbs Tower (33.0lb) Physical Weight lbs RM N/A Physical Dimension mm Tower 145x400x220 Physical Dimension inch Tower (5.7 Physical Dimension mm RM N/A Physical Dimension inch RM N/A INDICATOR LCD Indicators Status Line input (green), inverter output (green), bypass (yellow), fault (red) LED LED ALARM Alarm Battery Discharge The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition Alarm UPS Fault Continuous beeping sound INTERFACE Interface Dry Contact Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems Interface RS-232 Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems Interface Option N/A ENVIRONMENT Environment Temperature 0 deg C ~ 40 deg C Environment Humidity 0%~95% (Non condensing) ShowOrder 76 |
[Disclaimer for Product Information] |
|
||
|