Product Description:
OPTI-UPS Durable Series "B"
provides true on-line power for servers, workstations and other mission
critical equipments. On-line operation regulates the incoming AC power
and continuously offers connected applications with pure, stable sine
wave output. The power capacity allows you to work through short
blackouts or safely shut down after saving important files during
longer ones. OPTI-UPS Durable Series "B" has 4 to 12 outlets (depending
on voltage and capacity), multi-lingual and multi-functional LCD
display, built-in serial port that works with FREE OPTI-SAFE Xtreme
software to manage all kinds of power information and problems.
Moreover, Durable Series "B" offers SNMP card and USB port interface
for extra option in network management.
|
 |
Suggested Applications |
| |
|
Power-sensitive
applications, electronic measurement devices, corporate and
departmental servers, UNIX servers / workstations, CAD / CAM / CAE
workstations, network workstations, hubs / routers / bridges, and other
mission critical equipments.
|
|
| |
| |
 |
Features & Benefits
|
| |
|
True on-line protection
Zero transfer time
Independent Outlet Control
Powerful LCD front panel
High efficiency mode
Voltage can be selected
Smart fan speed control
Extended battery pack
Battery is replaceable by users
Remained battery backup time
SNMP card and built-in USB
interface
|
|
| |
|
| |
 |
Specifications
|
|
|
|
Model name
|
DS3000B
|
|
Topology
|
On-Line, Double
Conversion, Single Phase (2W+G)
|
|
On-battery Output Wavefrom
|
Sine Wave
|
|
INPUT
|
|
Miximum Capacity
|
3000VA / 2100W
|
|
Nominal Input Voltage
|
100/110/120V or
220/230/240V
|
|
Input Voltage Regulation
|
80-144Vac or 160-276Vac
|
|
Nomina Input Frequency
|
50/60Hz Auto sensing
|
|
Input PFC
|
>0.97 at Full load
|
|
Input Short Protection
|
Circuit Breaker
|
|
AC line receptacle
|
100/110/120V models
|
NEMA 5-30R
|
|
|
220/230/240V models
|
Depends on local
standards
|
|
OUTPUT
|
|
Nominal Output Voltage
|
100/110/120Vac or
220/230/240Vac
|
|
Output Voltage Regulation
|
Rated Voltage +/- 2%
|
|
Output T.H.D
|
< 3% T.H.D at Linear
Load
|
|
High Efficiency Mode(Ac to AC)
|
>95%
|
|
Crest Factor
|
3:1
|
|
Start on Battery
|
Yes
|
|
Auto Restart
|
Yes
|
|
Type and Number of Outlets
|
100/110/120V models
|
12 x NEMA 5-15R
|
|
|
220/230/240V models
|
8 x IEC 320 C13
|
|
|
1 x IEC 320 C19
|
|
|
PROTECTION
|
|
Data Line Protection
|
RJ11 / RJ45
|
| Surge Energy Rating |
1050 Joules
|
|
USER REPLACEABLE BATTERY
|
|
User Replaceable Battery
|
12V / 9AH x 6
|
|
Back-up Time (Full load / Half load)*
|
5/15 min.
|
|
Typical Recharge Time to 90%
|
<4 Hours
|
|
Extended Battery Pack
|
BP1000
|
|
MONITORING
|
|
Front Panel LEDs
|
AC mode,On lone,On
battery ,Bypass, fault, Overload and 15 UPS Parameters
|
|
Audible Alarms
|
Battery mode, UPS fault,
Overload
|
|
COMMUNICATION INTERFACE
|
|
Communication Port *
|
RS232 and USB Prot
|
|
SNMP
|
SNMP card accessory
available
|
|
ENVIRONMENTAL PARAMETERS
|
|
Operating Temperature
|
0°~40°C /
32°~104°F
|
|
Storage Temperature
|
-20°~60°C /
-4°~140°F
|
|
Relative Humidity
|
0~95% humidity ,
non-condensing
|
|
Audible Noise
|
< 40 dBA
|
|
PHYSICAL PARAMETERS
|
|
Dimensions(LxWxH):
|
Physical
|
16.7x8.9x14.2inch /
425x225x360 mm
|
|
Packing
|
20.7x13.8x19.1 inch /
526x350x485 mm
|
|
Weight:
|
Net
|
79.7 lb / 34.1 kg
|
|
Gross
|
84.6 lb / 36.8 kg
|
|
CONFORMANCE
|
|
Approvals
|
BSMI; CE; GOST-R;
UL/cUL; C-Tick; A-Tick
|
|
|