|
POWERCOM
POWERCOM ULTIMATE RACKMOUNT SERIES (ULT-3000RM) 3000VA,Rackmount Design (3U),RS-232 port,UPSMON s/w,SNMP / True on-line UPS, Double Conversion Design, Double CPU Control, Pure Sine Wave Output |
|
INTERNATIONAL GROUND SHIPPING: For qualified orders, we will waive the Brokerage/Handling Fee for Custom Clearance and Documentation No other hidden fees will be collected from you when packages arrive. Guaranteed [ Detailed Explanation ] |
Product Description: GENERAL INFORMATION Model Type ULTIMATE LED RM Model Name ULT-3000 RM LED Power Rating 3KVA/2100W AC INPUT AC Input Voltage 100V:76V~130V 110V:80V~138V 115V:83.5V~140V 120V:87V~140V 208V:152V~260V 220V:160V~276V 230V:167V~280V 240V:174V~280V AC Input Frequency 50 or 60 Hz+/-3 Hz AC Input Phase Single AC Input Power factor >= 0.98 AC OUTPUT AC Output Voltage 100V/110V/115V/120V or 208V/220V/230V/240V AC Output Frequency 50Hz/60Hz (Auto detection) AC Output Frequency Stability (+/-0.5%) AC Output Voltage Regulation (+/-2%) AC Output Powerfactor 0.7 (lagging) AC Output Hamonic distortion <3% of T.H.D. at linear load AC Output Overload detection 105% for 10 seconds and 130% +/- 10% for 300ms EFFICIENCY Field49 > 85% TRANSFER Transfer Power failure Recovery 0 ms Transfer Overload Disappear Auto transfer to UPS Transfer UPS to By Pass or Vice Versa N/A NOISE Noise Level 1m Distance < 45dBA PROTECTION Protection Spike 150 Joules BATTERY Battery Type Sealed lead acid battery, free-maintenance Battery Protection Cut off without draining any current when battery low Battery DC Voltage 72V BACKUP TIME Battery Backup Time Full Load 9 minutes Battery Backup Time Half Load 25 minutes Battery Recharge Time About 8 hours to 90% after fully discharged PHYSICAL Physical Weight lbs Tower N/A Physical Weight kgs RM 32 Physical Weight lbs RM (70.4lb) Physical Dimension mm Tower N/A Physical Dimension inch Tower N/A Physical Dimension mm RM 130x480x130 Physical Dimension inch RM (16.9 INDICATOR LCD Indicators Status Line input (green), inverter output (green), bypass (yellow), fault (red) LED LED ALARM Alarm Battery Discharge The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition Alarm UPS Fault Continuous beeping sound INTERFACE Interface Dry Contact Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems Interface RS-232 Provide power management & diagnostic functions including power status, battery low, schedule UPS ON/OFF, battery/load level display and more. Compatatible with Windows 95/98/2000/ME/NT/XP, Novell Unix and other popular systems Interface Option N/A ENVIRONMENT Environment Temperature 0 deg C ~ 40 deg C Environment Humidity 0%~95% (Non condensing) ShowOrder 85 |
[Disclaimer for Product Information] |
|
||
|