|
POWERCOM
POWERCOM SMART KING SERIES (SMK-2000A) 2000VA, DB-9 + RS232 + UPSMON S/W, ABM, HSB,SNMP for Smart Sine Wave UPS +AVR with Internet Protection |
|
INTERNATIONAL GROUND SHIPPING: For qualified orders, we will waive the Brokerage/Handling Fee for Custom Clearance and Documentation No other hidden fees will be collected from you when packages arrive. Guaranteed [ Detailed Explanation ] |
Product Description: Here is a successful case for PCM global system of power management. Currently, inside Turkey, there are 1228 serial products of Smart King, wireless UPS of Ultimate series, and over 5000 hosts, and all of them are monitored via the Internet at the same time. This is the realization of remote system of power management and protection of automatic stop when no one is in the office. GENERAL INFORMATION Model Type SMART KING Model Name SMK-2000A AC INPUT AC Input Capacity on Battery 2000VA AC Input Voltage (+/-) 25% at line input AC Input Frequency 50 or 60 Hz+/-5% (auto sensing) AC OUTPUT AC Output Voltage Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning AC Output Frequency 50 or 60 Hz +/- 0.5% AC Output Voltage Regulation AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal PROTECTION Protection Spike 320 Joules, 2ms Protection EMI/RFI 10dB at 0.15 MHz, 50 dB at 30 MHz Protection Overload UPS automatic shutdown if overload exceeds 110% nominal at 20 sec and 125% at 5 sec Protection Unit Fuse for 110V models (600VA~2500VA) and 220V models (under 1250VA), breaker for 110V model (3000VA) and 220V models (above 1500VA) Protection Transfer Time 2/4 milliseconds (typical), including detection time Protection Short Protection UPS output cut off immediately or input fuse( or breaker) protection BATTERY Battery Type Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 year lifetime Battery Typical 4 hours (to 90% of full capacity) Battery Protection Automatic self-test & discharge protection, replace battery indicator Battery Run Time ~ 120 minutes PHYSICAL Physical Weight kgs Tower 30 Physical Weight lbs Tower (66.0lb) Physical Weight lbs RM N/A Physical Dimension mm Tower 170x450x226 Physical Dimension inch Tower 6.7x17.7x8.9 INDICATOR LCD Indicators Status Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status, load LED LED ALARM Alarm Battery Backup Slow beeping sound (about 0.25 Hz) Alarm Battery Low Rapid beeping sound (about 1.00Hz) Alarm Overload Continue beeping sound INTERFACE Interface Dry Contact Sends AC fail and battery low signals, and receives shutdown signal from computer Interface RS-232 Detect battery low, Schedule UPS on/off, AC input/output power status display Interface Option Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP ENVIRONMENT Environment Ambient 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-48 deg c Environment Audible <40dBA (1 meter from surface) Environment Storage Condition 15,000 meters max. elevation ShowOrder 33 |
[Disclaimer for Product Information] |
Recently Viewed Products |
|
||
|