SYSTEM OVERVIEW |
System overview:
|
Medical Grade tower line interactive UPS system
includes built-in isolation transformer with faraday shield, line
interactive voltage regulation, high quality hospital-grade plug and
outlets. AC surge suppression, DB9 communications port and two line
TEL/DSL modem protection. UL2601-1 listed as medical electrical
equipment with less than 300 microamps cumulative leakage current for
UPS and all connected loads.
|
Voltage compatibility:
|
120 V AC
|
Frequency compatibility:
|
60 Hz.
|
OUTPUT |
Output volt amp capacity (VA):
|
330
|
Output watt capacity (watts):
|
225
|
Output nominal voltage:
|
120V Nominal
|
Output voltage regulation:
|
LINE MODE: Sine wave line voltage 120V (-18% /
+8%)
BATTERY MODE: PWM sine wave output 120V +/-5%
|
Output frequency regulation:
|
LINE MODE: Passes line frequency of 60Hz.
+/-10%
BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
|
Outlet quantity / type:
|
4 NEMA 5-15R HG
|
INPUT |
Maximum input amps:
|
2.3A / 250 watts
|
Input connection type:
|
NEMA 5-15P Hospital-Grade
|
Input cord length:
|
6 ft, 14 gauge
|
Recommended electrical service:
|
15A 120V
|
BATTERY |
Full load runtime:
|
18 minutes (330VA)
|
Half load runtime:
|
46 minutes (165VA)
|
DC system voltage:
|
12 VDC
|
Typical battery lifespan:
|
3-6 years, depending on usage
|
Battery recharge rate:
|
2-4 hours to 90%
|
Replacement Battery Cartridge:
|
RBC52 (quantity 2)
|
VOLTAGE REGULATION |
Voltage regulation description:
|
Line interactive UPS offers a single boost
level of brownout correction to maintain usable, computer grade output.
|
Direct pass through:
|
Input voltages between 108 and 147V AC are
passed through unchanged
|
Brownout correction:
|
Input voltages between 83 and 107V AC are
boosted by 14%
|
LEDS ALARMS & SWITCHES |
Front panel LEDs:
|
Yes, includes 4 front-panel status indicator
LEDs for line power, battery power, voltage regulation and battery
low/replace status
|
Alarms:
|
Audible alarm indicates power failure
conditions, silenceable via alarm cancel switch. Once cancelled, alarm
will resume when approximately 2 minutes of battery operation remain
(assuming full load).
|
Switches:
|
Yes, includes 2 front panel mounted push-button
switches for system enable, self-test and alarm cancel functions
|
SURGE / NOISE SUPPRESSION |
AC suppression response time:
|
Instantaneous
|
Dataline suppression:
|
2-Line Tel/DSL
|
EMI / RFI AC noise suppression:
|
Yes
|
PHYSICAL |
Shipping weight (lbs):
|
26.5
|
Shipping weight (kg):
|
12.0
|
Unit weight (lbs):
|
25
|
Unit weight (kg):
|
11.4
|
Unit Dimensions (HWD/in):
|
10.75 x 5.25 x 7.25
|
Unit Dimensions (HWD/cm):
|
27.3 x 13.3 x 18.4
|
Material of construction:
|
PVC
|
Form factors supported:
|
Tower
|
Cooling method:
|
Convection
|
Battery Access:
|
Battery access door allows hot swap battery
replacement without powering connected equipment off
|
ENVIRONMENTAL |
Operating Temperature:
|
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
|
Storage Temperature:
|
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
|
Relative Humidity:
|
0 to 95%, non-condensing
|
COMMUNICATIONS |
Network monitoring port:
|
DB9
|
Software and cabling included:
|
Ships with DB9 cable, PowerAlert software
available via free download from www.tripplite.com
|
LINE / BATTERY TRANSFER |
Transfer time from line power to
battery mode:
|
2-4 milliseconds
|
Low voltage transfer to battery power:
|
83V (resets to line power as voltage increases
to 87V)
|
High voltage transfer to battery power:
|
147V (resets to line power as voltage decreases
to 143V)
|
CERTIFICATIONS |
Certifications:
|
UL1778 (USA, Series AGOM350KSR57HG), UL2601-1
(Medical), cUL (Canada), Class B (emissions), FCC Part 68 / Industry of
Canada (telecommunications)
|
WARRANTY |
Optional coverage:
|
3 year, 5 year, next day and on-site warranty
coverage available
|
Product warranty:
|
2 year product warranty
|
SPECIAL FEATURES |
Cold Start:
|
Yes, inverter can be "cold started" to enable
temporary AC output during a power failure
|
Appearance:
|
Attractive gray tower UPS
|