SYSTEM OVERVIEW |
System overview:
|
Online, double conversion rack / tower UPS
system continuously maintains near-perfect output power for critical
internetworking and telecommunications equipment. Uses only 9 rack
spaces (9U) in EIA standard rackmount configuration, with full support
for upright tower and stacking applications. Completely regenerates
input power into perfectly regulated sine wave output free of harmonic
distortion, fast electrical impulses and frequency fluctuations.
Simultaneously compatible with North American 208/240 and 120V
applications. Maintains output within 2% of nominal during brownouts to
156 and overvoltages to 276V. Supports enhanced monitoring of UPS and
line power conditions via DB9 serial port, included PowerAlert
monitoring software and complete cabling. Includes slot for
SNMPWEBCARD. Hardwire input / output connections supported. Runtime is
expandable with BP240V10RT3U battery packs.
|
Voltage compatibility:
|
Supports continuous high/low voltage output of
200, 208, 220, 230, 240 and 100, 120V AC over an input voltage range of
156-276V AC
|
Frequency compatibility:
|
50/60Hz
|
OUTPUT |
Output volt amp capacity (VA):
|
10000
|
Output watt capacity (watts):
|
7000
|
Output nominal voltage:
|
200, 208, 220, 230 or 240V AC and 100, 120VAC,
supports simultaneous High / Low output voltage
|
Output voltage regulation:
|
Maintains pure sine wave output at all times,
regulated within 2% of selected nominal output voltage, less than 5%
total harmonic distortion
|
Output frequency regulation:
|
Regulates line frequency to 50/60Hz +/- 0.05Hz
|
Outlet quantity / type:
|
Hardwire
|
Overload protection:
|
Resettable 63A circuit breaker
|
INPUT |
Maximum input amps:
|
50A / 8240 watts max.
|
Input connection type:
|
Hardwire
|
Recommended electrical service:
|
50A 208V
|
BATTERY |
Full load runtime:
|
Included batteries — 8 min. (10,000VA)
1 BP240V10RT3U — 19 min.
|
Half load runtime:
|
Included batteries — 20 min (5,000VA)
1 BP240V10RT3U — 45 min.
|
Expandable battery runtime:
|
Supports extended runtime with optional
external battery pack BP240V10RT3U (multi-pack compatible)
|
DC system voltage:
|
240 V DC
|
Typical battery lifespan:
|
3-6 years, depending on usage
|
Battery recharge rate:
|
2-4 hours to 90%
|
VOLTAGE REGULATION |
Voltage regulation description:
|
On-line, double-conversion process give this
UPS the ability to maintain output voltage within +/-2% of selected
nominal voltage at all times
|
Overvoltage correction:
|
Maintains continuous operation without using
battery power during overvoltages to 276V AC, reducing output within 2%
of selected nominal
|
Brownout correction:
|
Maintains continuous operation without using
battery power during brownout / undervoltage conditions to 156V AC,
increasing output within 2% of selected nominal
|
LEDS ALARMS & SWITCHES |
Front panel LEDs:
|
6 LED DISPLAY: line power, bypass, inverter,
charger, output AC and battery operation
SELECTABLE LCD DISPLAY: input/output voltage, Hz, battery voltage and
charge level and detailed warnings regarding all major UPS functions
|
Alarms:
|
Multi-function audible alarm offers
notification of UPS start, backup operation, low battery, overload, UPS
fault, inverter fault, DC bus fault, overtemperature, remote shutdown,
shutdown imminent and shutdown complete
|
Switches:
|
Includes main power off/on switch, plus 2
switches to set and execute scrollable LCD functions
|
SURGE / NOISE SUPPRESSION |
AC surge suppression:
|
Conforms to IEEE 587 / ANSI C62.41
specifications
|
AC suppression response time:
|
Instantaneous
|
EMI / RFI AC noise suppression:
|
Yes
|
PHYSICAL |
Shipping weight (lbs):
|
343.5
|
Shipping weight (kg):
|
155.9
|
Unit weight (lbs):
|
Power Module: 53.5 lbs., Battery Pack: 136.5
lbs., Step-down Transformer: 100 lbs.
|
Unit weight (kg):
|
Power Module: 24kg, Battery Pack: 61kg,
Step-down Transformer: 45kg
|
Unit Dimensions (HWD/in):
|
Power Module 5.14 x 17.5 x 22.5, Step-down
Transformer 5.14 x 17.5 x 26, Battery Pack 5.25 x 17.5 x 23.5
(Step-down transformer max depth is 24 inches when compatible SUPDM
backplate is used)
|
Unit Dimensions (HWD/cm):
|
Power Module 13.1 x 44.5 x 57.2
Step-down Transformer 13.1 x 44.5 x 66
Battery Pack 13.1 x 44.5 x 57.2
|
Material of construction:
|
Steel
|
Form factors supported:
|
Supports 9U rackmount installation in 4 post
rack enclosures. 2 post rackmount installation supported with optional
2POSTRMKIT (3 required). Upright tower installation supported with
included tower stands
|
Cooling method:
|
Built-in cooling fan
|
Battery Access:
|
User replaceable, hot swappable external
battery pack
|
ENVIRONMENTAL |
Operating Temperature:
|
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
|
Storage Temperature:
|
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
|
Relative Humidity:
|
0 to 95%, non-condensing
|
COMMUNICATIONS |
Network monitoring port:
|
Includes 2 built-in DB9 monitoring ports
(1-RS232 / 1-contact closure)
|
Software and cabling included:
|
Includes PowerAlert UPS monitoring software for
all common network and standalone operating systems. Cabling included.
|
SNMP compatibility:
|
Built-in accessory slot accommodates internal
SNMP / Web card and other network accessories
|
LINE / BATTERY TRANSFER |
Transfer time from line power to
battery mode:
|
Zero, online UPS continuously converts incoming
AC to DC, then back to AC. When line power is interrupted, UPS
maintains continuous output from battery reserves with absolutely no
disruption in output AC power.
|
Low voltage transfer to battery power:
|
Maintains continuous operation during
undervoltages as low as 156V AC. Below this point, output is maintained
utilizing battery reserves.
|
High voltage transfer to battery power:
|
Maintains continuous operation during
overvoltages to 276V AC. Above this point, output is maintained
utilizing battery reserves.
|
CERTIFICATIONS |
Certifications:
|
UL1778 (USA), cUL (Canada), CE (Europe), FCC
Class A (emissions), NOM (Mexico)
|
MANUFACTURERS WARRANTY |
Optional coverage:
|
3 year, 5 year, next day and on-site warranty
coverage available for select opportunities - contact Tripp Lite
|
Product warranty:
|
2 year product warranty
|
Connected equipment insurance (USA and
Canada Only):
|
$250,000 connected equipment insurance (USA and
Canada only)
|
SPECIAL FEATURES |
EPO port:
|
Includes dedicated EPO (emergency power off)
interface and cabling
|
Cold Start:
|
Yes, inverter can be "cold started" to enable
temporary AC output during a power failure
|
Appearance:
|
Attractive black steel rackmount housing
|
BATTERY PACK ACCESSORY (optional) |
Battery Pack Accessory (optional):
|
BP240V10RT3U (optional)
|